Open Access Open Access  Restricted Access Subscription or Fee Access

Micro-cantilever Sensors for Efficient Gas Sensing

Sukumar Basu, Deepika Saxena, Arnab Hazra

Abstract


Abstract

Micro-cantilever has been progressively used for the development of miniaturized sensors for gas sensing, biochemical analysis, medical applications and quality and process control. Micro-cantilevers are fabricated with rectangular silicon slabs having thickness below 1 µm. For gas sensing applications, Si cantilever surface is modified with appropriate sensing materials for selective adsorption of gas/vapor or biomolecules. The bending of the cantilever due to different surface conditions is measured with laser beam deflection to get the sensitivity of the sensor. The current article discusses the background, principle of operation and bending characteristics of micro-cantilever gas sensors. Various applications and applicability of the micro/nano cantilever gas sensors have also been covered in the present report. Finally, the article has been concluded with future prospects of microcantilever gas sensors for multiple potential applications.

Keywords: Microcantilever, gas sensing, fast response, selectivity, biosensor

Cite this Article

Deepika Saxena, Arnab Hazra and Sukumar Basu. Micro-cantilever Sensors for Efficient Gas Sensing. Journal of Semiconductor Devices and Circuits. 2019; 6(3): 16–24p.



Full Text:

PDF

References


Balselt DR, Fruhberger B, Klassen E, Cemalovic S, Britton Jr CL, Patel SV, Mlsna TE, McCorkle D, Warmack B. Design and performance of a micro cantilever-based hydrogen sensor. Sens Act B. 2003;88:120–131.

Chapman PJ, Vogt F, Dutta P, Datskos PG, Devault GL, Sepianiak MJ. Facile hyphenation of gas chromatography and a microcantilever array sensor for enhanced selectivity. Anal Chem. 2007;79:364–370.

Hu Z, Thundat T, Warmack RJ. Investigation of adsorption and adsorption-induced stresses using microcantilever sensors. J Appl Phys. 2001;90:427–431.

Itoh T, Suga T. Force sensing microcantilevers using sputtered zinc-oxide thin-film. Appl Phys Lett. 1994;64:37–39.

Kooser A, Gunter RL, Delinger WD, Porter TL, Eastman MP. Gas sensing using embedded piezo resistive microcantilever sensors. Sens Act B. 2004;99:474–479.

Mertens J, Finot E, Nadal MH, Eyraud V, Heintz O, Bourillot E. Detection of gas trace of hydrofluoric acid using microcantilever. Sens Act B. 2003;99:58–65.

Mertens J, Finot E, Nadal MH, Eyraud V, Heintz O, Bourillot E. Detection of gas trace of hydrofluoric acid using microcantilever. Sens Act B. 2003;99:58–65.

Muralidharan G, Wig A, Pinnaduwage LA, Hedden D, Thundat T, Lareau RT. Absorption-desorption characteristics of explosive vapors investigated with microcantilevers. Ultramicroscopy. 2003;97:433–439.




DOI: https://doi.org/10.37591/josdc.v6i3.3622

Refbacks

  • There are currently no refbacks.


Copyright (c) 2020 Journal of Semiconductor Devices and Circuits

Publisher: STM Journals, an imprint of CELNET (Consortium e-Learning Network Pvt. Ltd.)

Address: A-118, 1st Floor, Sector-63, Noida, Uttar Pradesh-201301, India

Phone no.: 0120-478-1215/ Email: [email protected]