Open Access Open Access  Restricted Access Subscription or Fee Access

A Seismic Analysis of R.C. Structures Under Tuned Mass Damper System.

Rutuja prashant kulkarni, V.R. Upadhye, M.N. Mangulkar

Abstract


A Seismic Analysis of R.C. Structures Under Tuned Mass Damper System treats seismic force reduction of multi-storey buildings using embedded dampers. tuned mass damper is investigated. Dynamic analysis was carried out using Etabs to obtain the damped and undamped responses of the structure in terms of deflections at all storeys in order to evaluate the effectiveness of the damping system to reduce the seismic response. The earthquake zone v used in this study has been applied on the structure in the horizontal plane. Concrete material properties were chosen to represent the model as many high-rise buildings are constructed by using reinforced concrete.


Keywords


Tuned mass Dampers; tip displacement; frequency; Etabs; Equivalent static analysis; Equivalent Dynamic analysis

Full Text:

PDF

References


F. Rudinger, “Tuned mass damper with fractional derivative damping.” pp.1774–1779, Engineering Structures 28 (2006).

IS Code 1893-2016 (part 1) Criteria for Earthquake Resistant Design of Structures.

Nam Hoang, Yozo Fujino, “Optimal tuned mass damper for seismic applications and practical design formulas.” Engineering Structures 30, pp. 707–715, (2008).

Dr. Mohan M. Murudi and Mr. Sharadchandra M. Mane, “Seismic effectiveness of tuned mass damper (TMD) for different ground motion parameters.” 13th World Conference on Earthquake Engineering, Canada 1-6, (2004).

Carlos A. Martínez, Oscar Curadelli, María E. Compagnoni, “Optimal design of passive viscous damping systems for buildings under seismic excitation.” Pp. 253-264, vol.90, (2013).

R.N. Jabary, S.P.G. Madabhushi, “Tuned mass damper effects on the response of multi-storied structures observed in geotechnical centrifuge tests.” Soil Dynamics and Earthquake Engineering, vol.77, pp.373–380, (2015).

H. Gao and K. C. S. Kwok, “Optimization of tuned liquid column dampers.” Engineering Structures, Vol. 19, No. 6, pp. 476-486, (1997).

Chi-Chang Lin, Jin-Min Ueng, Teng-Ching Huang, “Seismic response reduction of irregular buildings using passive tuned mass dampers.” Engineering Structures, pp. 513–524, vol. 22, (1999).

Y.L. Xu, Q. He, J.M. Ko, “Dynamic response of damper-connected adjacent buildings under earthquake excitation.” Engineering Structures, pp. 135–148, vol. 21, (1999).




DOI: https://doi.org/10.3759/josem.v6i1.1445

Refbacks

  • There are currently no refbacks.