Automated Diesel transfer system using PLC
DOI:
https://doi.org/10.3759/joise.v6i1.1571Abstract
Programmable Logic Controller (PLC) is used in many small and large scale process/production industries. In this paper, PLC is used to control the transfer of diesel required for the diesel generator (DG) when the main/local power supply goes off. A modelling of a diesel transfer system using PLC provides an effectual method to maintain uninterrupted power supply to continue the process/production which helps to maintain quality, reduced human intervention and provides safety to the equipment & system by having interlocks. Siemens PLC & Siemens Totally Integrated Automation (TIA) Portal are used to model & simulate this automated system respectivelyReferences
B.I.Aldi, J.S.Kadadevarmath, N.P.Bannibagi, Design and Implementation of a PLC-based Electricity Supply Switching Control System, IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE), Volume 11, Issue 3 Ver. III (May. – Jun. 2016), PP 43-50
P. K. Bhowmik, M. Dey and S. K. Dhar, PLC Based Operation and Control of Two Diesel Generator Set, Journal of Electrical Engineering J. Elec. Engg., Instn. Engrs., Bangladesh, 36(II), December 2009.
W. Bolton, Programmable Logic Controller, Burlington, MA 01803, Elsevier Newnes, 2006.
Sandeep S.R, Chaithra H.B, Pavithra K.N, et al. PLC Based Monitoring System of Diesel Generator. International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. Vol. 5, Issue 5, May 2016.
CPU 31xC and CPU 31x: Technical specifications Manual, 03/2011, A5E00105475-12.
Downloads
Additional Files
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |