Reliability Analysis of a Semi-gravity Retaining Wall Designed to Eurocode 7
Abstract
This research investigated the structural integrity of a semi-gravity retaining wall when subjected to potential sliding and overturning failures, while adhering to the guidelines outlined in Eurocode 7. It is widely acknowledged that the factor of safety alone is insufficient for risk assessment, and previous research has demonstrated the challenges in identifying how much safer a retaining wall becomes as the factor of safety increases. The dependability index, the element of safety, and the failure probability are all investigated in this study. This relationship was investigated by varying the height and bottom width of the wall, which were controlled by Eurocode 7 limit state functions in sliding and overturning. In the first order reliability approach (FORM), the Hasofer-Lind formulation was used. While Microsoft Excel was used for the reliability analysis technique, the results of the extra analysis showed that the reliability index was a better predictor of failure than the factor of safety in both cases of sliding and overturning failure of the retaining wall. While the factor of safety would either remain constant (as in the case of overturning failure with varying bottom widths) or show a smaller change in values In instances of sliding failure with varied bottom widths, the analysis revealed a consistent relationship: as the reliability index increased, the probability of failure consistently decreased.
References
Baecher, G. B. and J. T. Christian (2003). Reliability and Statistics in Geotechnical Engineering, John Wiley and Sons Inc.
Braja, M. D. (2011). Principles of Foundation Engineering, Seventh Edition, Global Engineering, Cengage Learning, Stamford.
Christian, J. T. (2004). “Geotechnical Engineering Reliability: How well do we know what we are doing?” Journal of Geotechnical and Geoenvironmental Engineering, 130, 985.
Duncan, J. M. (2000), “Factors of Safety and Reliability in Geotechnical Engineering,” Journal of Geotechnical and Geoenvironmental Engineering, ASCE, 126, 307 – 316.
EN 1997-1: EuroCode 7 (2004) “Geotechnical design - Part 1: General rules”
Fenton G., Griffiths D. and Williams, (2005). “Reliability of Traditional Retaining Wall Design,” Geotechnique, 55, 55-62.
Ji, J., Zhang, C., Gao, Y., Kodikara, J., (2018). “Effect of 2D spatial variability on slope reliability: a simplified FORM analysis.” Geoscience Frontiers 9, (6), 1631-1638.
Lacasse, S. and Nadim, F., “Risk and Reliability in Geotechnical Engineering” (1998). International Conference on Case Histories in Geotechnical Engineering. 11.
Low, B. K. (2005). “Reliability-based design applied to retaining walls”, Geotechnique, Vol. 55, No. 1, 63-75.
Low, B.K., and Tang, W.H. (2007). “Efficient spreadsheet algorithm for first-order reliability method”, Journal of Engineering Mechanics, 1378–1387. doi:10.1061/(ASCE)07339399(2007)133:12(1378)
Manoj, N. R. (2016). First - order Reliability Method: Concepts and Application. [Graduation Thesis, Delft University of Technology].
Phoon, K. K. (2005). Reliability- Based Design Incorporating Model Uncertainties. 3rd International Conference on Geotechnical Engineering combined with 9th Yearly Meeting of the Indonesian Society for Geotechnical Engineering, Samarang, Indonesia.
Sadaf, Q. and Indra, H. (2012). Geotechnical Uncertainties and Reliability Theory Applications. International Journal of Engineering Research & Technology (IJERT), vol. 1, Issue 6.
Sujith, M. S., Devdas Menon, and Dodagoudar G. R., (2011). “Reliability analysis and design of cantilever RC retaining walls against sliding failure.” International Journal of Geotechnical Engineering, 131-141.
Whitman, R. V. (2000). “Organizing and Evaluating Uncertainty in Geotechnical Engineering,” Journal of Geotechnical and Geoenvironmental Engineering, ASCE, 126, 583-593.
Zhang, W., and Goh, A. T. C. (2018). Reliability analysis of geotechnical infrastructures: introduction. Geoscience Frontiers, 9(6), 1595‑1596.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |