Optimisation of the Experimental Methods for the Fabrication of Polymer Microstructures and Polymer Microfluidic Devices for Bioengineering Applications
Keywords:
Polymers, lithography, microstructures, microfluidic devices, cleanroomAbstract
In this research paper, total 2278 individual polymer microstructures have been fabricated, measured and analyzed. Also, in this research paper, total 216 individual polymer microfluidic devices have been fabricated by the maskless lithography, hot embossing lithography, direct bonding technique, and indirect bonding technique, to record and analyze the surface-driven (passive) capillary flow individually in each microfluidic device. Total three individual polymers as SU8, polymethylmethacrylate (PMMA), and polyimide have been used to fabricate all of the microstructures and all microfluidic devices reported in this research paper. Total 30 individual electrical and non-electrical instruments (including the equipment of the cleanroom laboratory) have been used to perform all the experiments of this research paper. These fabricated polymer microstructures are applied in the microfluidic devices for bioengineering applications. The author has performed all the experiments of this research paper using his own hands-on completely. The optimisation of experimental methods is a novel approach in this research paper.Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |