Fault Tolerant Inverter for BLDC Drives

Authors

  • Bindhuja S. Student, Department Electrical and Electronics Engineering, Rajiv Gandhi Institute of Technology, Kottayam, Kerala, India
  • Sreelekha V. Assistant Professor, Department of Electrical and Electronics Engineering, Rajiv Gandhi Institute of Technology, Kottayam, Kerala, India

DOI:

https://doi.org/10.37591/.v8i3.1312

Abstract

In this study, fault tolerant inverter for BLDC drives is used for aerospace application. In such application, the human intervention is limited. So, the fault tolerant control of BLDC motor is of great importance for its continuous operating capacity even under the faulty situation. Over voltage and over current phenomenon occur in system due to switching faults, so a fault isolation and system reconfiguration method is presented. This method can be used to avoid the secondary fault caused by direct switch of redundant switch and the faulty switch after the fault diagnosis process. Simulation results are obtained using MATLAB/Simulink.


Keywords: Brushless DC (BLDC) motor, buck converter, fault tolerant inverter topology, system reconfiguration

Cite this Article

Bindhuja S, Sreelekha V. Fault Tolerant Inverter for BLDC Drives. Journal of Power Electronics & Power Systems. 2018; 8(3): 31–38p.


Published

2018-12-06

Issue

Section

Research Article