Optimum Setting of Distance Protection Scheme for HV Transmission Line
DOI:
https://doi.org/10.37591/.v3i2.3152Abstract
Protective relays in a power system are used to detect system abnormalities and to execute appropriate commands to isolate swiftly only the faulty component from healthy system. One of the protective relay is the distance relay. When the fault occurs it is seen that large amount of current flows through the network. The distance relay detect the over current by measuring the impedance of the transmission line and send the tripping signal to the circuit breaker to isolate the power line. This paper focuses on determining the optimum setting and the performance of the distance relay when different types of faults occur in the system. The modeling and analysis of the test system with corresponding relay circuits have been carried out by using Power System Computer Aided Design PSCAD. From the simulation, it can be observed that the fault voltage, fault current, mho relay settings and its characteristics are consistent with those from the theoretical concept.
Keywords: high voltage transmission line, distance relay settings, Mho relay characteristics, PSCAD-EMTDC
Downloads
Published
Issue
Section
License
Journal Title:
Title of the Paper:
Corresponding Author’s Information:
Name: Address:
E-mail:
Contact Number:
It is herein agreed that: The copyright to the above-listed unpublished and original article is transferred to STM Journals.
This copyright transfer covers the exclusive right to reproduce and distribute the contribution, including reprints, translations, photographic reproductions, microform, electronic form (offline, online), or any other reproductions of similar nature.
I/We declare that above manuscript is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
I/ We warrant(s) that his/her/their contribution is original, except for such excerpts from copyrighted works as may be included with the permission of the copyright holder and author thereof, that it contains no libelous statements, and does not infringe on any copyright, trademark, patent, statutory right, or propriety right of others.
I/We will not publish his/her/their above said contribution anywhere else without the prior written permission of the publisher unless it has been changed substantially. I/We also agree to the authorship of the article in the following order: Author(s) Name Signature(s)
1. ________________
2. ________________
3. ________________
4. ________________
The author(s) agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal (comments if any to the editor can be added below).