This paper presents a fault tolerant control in four switch voltage source inverter by using PI controller. Four switch voltage source inverter has four switches with two legs and DC input link.  Four switch voltage source inverter (FSVSI)  can  produce a three phase ac voltage as in six switch three phase voltage source inverter with only a four power semiconductor switches in a short of two switches. The two switch fault circuit topology of a four switch voltage source inverter with three phase load is demonstrated with various switching mode conditions.In the event of either a single switching fault in any one of the legs or two switching faults in two legs simultaneously,  the proposed PI controller detects and minimizes the time between the fault occurrence and its isolation so as to the system remains in a healthy operation. To analyze the steady state and transient operating conditions of drives, space vector pulse width modulation technique is preferred to produce the necessary signals for each and every power switches under fault conditions. This paper presents two switching fault tolerant control scheme to control the system variables to drive the process and maintain the desired response by using proportional – integral (PI) algorithm. It establishes a PI based fault detection and isolation of two switching faults for four switch voltage source inverter with help of software MATLAB-SIMULINK. The simulation results of output voltage and dynamic characteristics of three phase induction motor under the faulty conditions are verified with fault recovery time.


Keywords


Fault detection, fault isolation, four switch voltage source inverter, PI controller, space vector pulse width modulation, three phase induction motor, two switch fault

Full Text:

PDF

References


Kastha D and Bose B.K.J ,“Investigation of fault modes of voltage-fed inverter system for induction motor drive”, IEEE Trans. Ind. Appl., pp. 1028–1038, 1994.

A. O’Dwyer, “Handbook of PI and PID controller tuning rules”,U.K.: Imperial College Press, 2nd edition, 2006.

A.O’Dwyer, Handbook of PI and PID controller tuning rules. London, U.K.: Imperial College Press, 1st edition, 2003.

R. Peuget , S. Courtine and J.Rognon , “ Fault detection and isolation on a PWM inverter by knowledge based model”, IEEE Trans.Ind.Appl.pp.1318-1325,1998.

M. N. Uddin, and M. A. Rahman, “Fuzzy Logic controller Based cost effective four switch three phse inverter fed IPM Synchronous Motor Drive,” IEEE Transactions on industry applications, vol. 42, no. 1, pp. 21-30,January/February 2006.

F. Blaabjerg, D. O. Neacsu and J. K. Pedersen, “Adaptive SVM to Compensate Dc-Link Voltage Ripple for Four-Switch, Three-Phase Voltage Source Inverter,” IEEE Trans. on Power Electronics, vol. 14, no. 4, pp.743-751, July 1999.

R. J. Cruise, C. F. Landy and M. D. McCulloch, “Evaluation of a Reduced Topology Phase-Converter Operating a Three-phase Induction Motor,” IEEE/IEMDC Conf., Seattle, USA,pp.466-468, Record 1999.

S. Takijawa, M. Tabata, T. Tanigawa, S. Igarashi and K. Kuroki,” High Efficiency Drive Techniques for the Brushless DC Motor Using a Four Switch Three-Phase Inverter,” Proceedings of IPEC, Japan, pp.1692-1697,2000.

T. M. Jahns, G. B. Kliman, and T. W. Neumann, “Interior Permanent Magnet Synchronous Motors for Adjustable-Speed Drives,” IEEE Transactions on Industry Applications, vol.IA-22, pp. 738-747, July/August 1986.

Matlab, Simulink User Guide, The Math Works Inc.,2003

R. L. A. Ribeiro, C. B. Jacobina, E. R. C. da Silva, and A. M. N. Lima,” AC/AC converter with four switch three phase structures,” In Proc. IEEE PESC, pp. 134–139, Jun. 1996.

D. T. W. Liang and J. Li, “Flux vector modulation strategy for a four-switch three-phase inverter for motor drive applications,” In Proc. IEEE PESC, pp. 612–617,Jun. 1997.

F. Blaabjerg, S. Freysson, H. H. Hansen, and S. Hansen, “A new op-timized space-vector modulation strategy for a component-minimized voltage source inverter”, IEEE Trans. Power Electon., vol. 12, no. 4, pp. 704–714, Jul. 1997.

F. Blaabjerg, D. Neacsu, and J. Pedersen, “Adaptive SVM to compen-sate DC-link voltage ripple for four-switch three-phase voltage-source inverters,” IEEE Trans. Power Electon., vol. 14, no. 4, pp. 1331–1337, Jul. 1999.

R. K. Pongiannan and N. Yadaiah, “FPGA based Space Vector PWM control IC for three phase induction motor drive,” in Proc. IEEEICIT, pp. 2061-2066,2006.

Y. Y. Tzou and H. J. Hsu, “FPGA realization of space vector PWM control IC for three phase PWM inverters,” IEEE Trans. Power Electron., vol. 12, no. 6, pp. 953-963,1997.

S. Karimi , P. Poure ,and S. Saadate , “Fast power switch failure detection for fault tolerant voltage source inverters using FPGA ,” IET Power Electron., vol. 2, Iss. 4, pp. 346–354. 2009.