Anti-static Additive and Particulate Formation in Jet Fuel at Low Temperature

Authors

  • George Wu Taknia Libya Engineering Company
  • Musbah Elzhawi Technical Affairs Department, Arabian Gulf Oil Company, Benghazi, Libya
  • Ezzedine Alsosi Sarir Laboratory, Sarir Oil Field, Arabian Gulf Oil Company, Libya
  • Walid Almughrabi Sarir Laboratory, Sarir Oil Field, Arabian Gulf Oil Company, Libya

DOI:

https://doi.org/10.37591/jopet.v9i2.2698

Keywords:

Libya, Tobruk refinery, Sarir refinery, Jet Fuel, Anti-Static Additive, Particulate, Low Temperature

Abstract

Over-dosed anti-static additive Stadis 450 can form particulates in jet fuel when temperature goes down to around -38oC. The particulate formation was observed during freezing point test. The jet fuel produced by Toruk refinery of Arabian Gulf Oil Company of Libya had freezing point of about -55OC which is lower than required-47OC for jet fuel A-1.

 

Key words: Libya, Tobruk refinery, Sarir refinery, Jet Fuel, Anti-Static Additive, Particulate, Low Temperature

Published

2019-09-03

Issue

Section

Articles