Design of Ducts: An Industrial Perspective
Keywords:
Packaged Unit, VRF, FCU, Exhaust Units, EFM, McQuayAbstract
Central Air Conditioners working is a complex and cumbersome topic which takes a lot of time and effort. It’s a difficult task to explain the entire parts, its working and maintenance. Here an effort is made to explain about the designing of Ducts used in a central A/C. A Commercial building is taken for reference and each floor’s Duct designing is explained. The ground floor is designed with supply air ducts with diffusers without any return air ducts. The first floor is designed with packaged units with return ducts. The second floor is divided into four zones and each zone is supplied with a different type of Air conditioner viz. Zone 1 is supplied with variable refrigerant flow (VRF) with cassette units supplying the air to the room. Zone 2 is supplied with VRF with duct able units without the return air ducts. Zone 3 is supplied with Fan Coil Units (FCU) with chilled water connection. Zone 4 is connected with dedicated VRF system with a designed temperature of 25°C and 25% RH. At the basement the exhaust units are placed. Initially the building survey is done and the commercial building details are studied in detail and the entire floor is divided into zones. Zone 1, Zone 2, Zone 3, Zone 4. For each of the zone the cooling load is calculated and the load found in BTU/hour is converted into tones of refrigeration. Based on this cooling load the ducts designing is done using the EFM (Equal Friction Method). Using the McQuay Software the dimensions of the ducts are decided. Once the dimensions are ready the layout of the building is designed with this Ducts setup in each floor as stated above. AUTOCAD Software was used for the entire design of the ducts. The entire building with the ducts design is provided for optimum air flow in each of the Zone of each floor as the results.References
Kumari KR, Reddy AR, Sagar MV. Design and Drafting of Hvac, Central Air Conditioning System For An Office Building. IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE).2016;44–50.
Vrellas CG, Karakatsanis TS. Calculation methods for a complete air conditioning study: Case study of an industrial installation. Structural Survey. 2012 Nov 2; 30(5):460–74.
Taecheol Kim Jeffrey D. Spitler, Ph.D., P.E. Ronald D. Delahoussaye, Ph.D.” Optimum Duct Design for Variable Air Volume Systems, Part 2: Optimization of VAV Duct Systems. ASHRAE Transactions: Research 105.
Wen Jian Cai Yao-Wen Wang, Wen-Jian Cai , Yeng-Chai Soh, Shu-Jiang Li, Lu, Lihua Xie “A simplified modeling of cooling coils for control and optimization of HVAC systems” Energy Conversion and Management 45 (2004) 2915–2930.
Pan JL, Chen SZ, Jain R, Paul S. Energy sensing and monitoring framework with an integrated communication backbone in the energy efficient intelligent buildings. In Applied Mechanics and Materials 2013 (Vol. 303, pp. 1460–1464). Trans Tech Publications Ltd.
Guang-Yu Jin a, Wen-Jian Cai a, Lu b, Eng Lock Lee b, Andrew Chiang “A simplified modeling of mechanical cooling tower for control and optimization of HVAC systems” Energy Conversion and Management 48 (2007) 355–365
Degu YM. Cooling Load Estimation and Air Conditioning Unit Selection for Hibir Boat. The International Journal of Engineering and Science (IJES) Vol. 2014 May; 3:2319–1813.
Hong T, Sun K, Zhang R, Schetrit O, Hinokuma R, Kasahara S, Yura Y.
Development and Validation of a New VRF Model in EnergyPlus. In ASHRAE Winter Conf., Orlando, FL, USA 2016.
Sharma GS, Sharma B. Duct designing in air conditioning system and its impact on system performance. VSRD International Journal of Mechanical, Automobile and Production Engineering. 2012 Nov;2(9).
Prashanth IS, Nikitha V, Aravind B, Mahesh N. Estimation of Cooling Load Calculations for a Commercial Complex. International Journal of Trend in Scientific Research and Development (IJTSRD). 2019; 3(3).
Hussain J.,Gaffar S. A. Heat Load Calculation. IJTSRD. 2019; 3(5):1233–1235.
Lu L, Cai W, Soh YC, Xie L, Li S. HVAC system optimization––condenser water loop. Energy Conversion and Management. 2004 Mar 1; 45(4):613–30.
Basavaraja KT, Kiran T, Sushanth T, Reddy TS. Heat Load Calculation with Duct Design of a MultiStoreyed Residential Building. International Journal of Trend in Scientific Research and Development (IJTSRD). 2019.
Wang YW, Cai WJ, Soh YC, Li SJ, Lu L, Xie L. A simplified modeling of cooling coils for control and optimization of HVAC systems. Energy Conversion and Management. 2004;45(18–19):2915–30.
Jin GY, Cai WJ, Lu L, Lee EL, Chiang A. A simplified modeling of mechanical cooling tower for control and optimization of HVAC systems. Energy conversion and management. 2007; 48(2):355–65.
A handbook of sheet metal and air conditioning contractor’s national association incorporation Sheet Metal and Air Conditioning Contractors' National Association.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |