Design of a HVAC System for an Entire Hotel
Keywords:
HVAC, Chillers, Fresh Air, CPVC Pipe, ISHRAE Data Book, Human Comfort Chart, HVAC System, Life Safety.Abstract
HVAC&R systems stands for (heating, ventilation, air conditioning and refrigeration). These systems are particularly used in thermal industries and other commercial offices. The main aim of the project is to design an energy efficient and cost efficient HVAC system for a given layout of a hotel. This project particularly deals with the heat load calculation, selection of materials, selection of systems taking into consideration of various factors like :- Structure Of Building, Glass Material, Path Of Sun, Climate And Atmospheric Condition Of The Given Area And Requirements Of The Customer. The project will follow all the HVAC safety standards provided by the ASHRAE (American society of heating, refrigeration and air conditioning engineers) and the norms regarding human comfort and also considering environmental aspects. The outcome of the project will be a plan of complete HVAC&R systems of the layout of the hotel with consideration of all the aspects including the latest technologies in HVAC industries.References
Sekhar SC. Space temperature difference, cooling coil and fan—energy and indoor air quality issues revisited. Energy and buildings. 2005;37(1):49-54.
Zajic I, Larkowski T, Sumislawska M, et al. Modelling of an air handling unit: a hammerstein-bilinear model identification approach;2011 Aug 16-18; Las Vegas, NV, USA, IEEE.2011.59-63.
Junaid Hussain | Syed Abdul Gaffar "Heat Load Calculation" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5, August 2019, pp.1233-1235, URL: https://www.ijtsrd.com/papers/ijtsrd26571.pdf.
Ribeiro E, Jorge HM, Quintela DA. HVAC system energy optimization in indoor swimming pools. 2011 Jul 7-9; Leiria, Portugal,IEEE;2011.1-7.
Bearg DW. Air sampling using a shared-sensor, vacuum-draw approach. ASHRAE Transactions. 1999;105:1089.
Li J, Hrnjak P. Improvement of condenser performance by phase separation confirmed experimentally and by modeling. International journal of refrigeration. 2017;78:60-9.
Masoero M. Inspection and Energy Auditing of HVAC Systems: Implementation of EPBD article 9.
Nasif M, Al-Waked R, Morrison G,et al.Membrane heat exchanger in HVAC energy recovery systems, systems energy analysis. Energy and Buildings. 2010;42(10):1833-40.
Fisk WJ, Brager G, Burge H,et al.Energy-related indoor environmental quality research: A priority agenda.
Usoro PB, editor. HVAC System Fault Diagnosis and Energy Optimization Using State-space Methods and Modern Control Theory. National Science Foundation; 1984.
Katipamula S, Armstrong P, Wang W,et al. Development of high-efficiency low-lift vapor compression system-final report. Pacific Northwest National Lab.(PNNL), Richland, WA (United States).2010.
Sekhar SC, Chong K. Heat pipe application for energy efficient air-conditioning in an animal care facility. InIAQVEC 2007-The 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings.2007:28-31.
Yu FW, Chan KT. Optimization of water-cooled chiller system with load-based speed control. Applied Energy. 2008;85(10):931-50.
Huang S, Zuo W. Optimization of the water-cooled chiller plant system operation. 2014 sep 10-12; Atlanta, GA ,ASHRAE.2014.
Sai BB, Swathi I, Prasanna KS,et al.Design of cooling tower. International Journal of Scientific & Engineering Research. 2013;4(5):1560.
Afshari F, Dehghanpour H. A Review Study On Cooling Towers; Types, Performance and Application. ALKÜ Fen Bilimleri Dergisi. 2018:1-0.
Kareem FA, Al-Dulaimi MJ, Lafta NS. Investigation the exergy performance of a forced draft wet cooling tower. International Journal of Engineering & Technology. 2018;7(4):2575-80.
Yu BF, Hu ZB, Liu M,et al. Review of research on air-conditioning systems and indoor air quality control for human health. International journal of refrigeration. 2009;32(1):3-20.
Goetzler W, Guernsey M, Young J,et al.The future of air conditioning for buildings. Navigant Consulting, Burlington, MA (United States); 2016.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |