Sekhar SC. Space temperature difference, cooling coil and fan—energy and indoor air quality issues revisited. Energy and buildings. 2005;37(1):49-54.
Zajic I, Larkowski T, Sumislawska M, et al. Modelling of an air handling unit: a hammerstein-bilinear model identification approach;2011 Aug 16-18; Las Vegas, NV, USA, IEEE.2011.59-63.
Junaid Hussain | Syed Abdul Gaffar "Heat Load Calculation" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5, August 2019, pp.1233-1235, URL: https://www.ijtsrd.com/papers/ijtsrd26571.pdf.
Ribeiro E, Jorge HM, Quintela DA. HVAC system energy optimization in indoor swimming pools. 2011 Jul 7-9; Leiria, Portugal,IEEE;2011.1-7.
Bearg DW. Air sampling using a shared-sensor, vacuum-draw approach. ASHRAE Transactions. 1999;105:1089.
Li J, Hrnjak P. Improvement of condenser performance by phase separation confirmed experimentally and by modeling. International journal of refrigeration. 2017;78:60-9.
Masoero M. Inspection and Energy Auditing of HVAC Systems: Implementation of EPBD article 9.
Nasif M, Al-Waked R, Morrison G,et al.Membrane heat exchanger in HVAC energy recovery systems, systems energy analysis. Energy and Buildings. 2010;42(10):1833-40.
Fisk WJ, Brager G, Burge H,et al.Energy-related indoor environmental quality research: A priority agenda.
Usoro PB, editor. HVAC System Fault Diagnosis and Energy Optimization Using State-space Methods and Modern Control Theory. National Science Foundation; 1984.
Katipamula S, Armstrong P, Wang W,et al. Development of high-efficiency low-lift vapor compression system-final report. Pacific Northwest National Lab.(PNNL), Richland, WA (United States).2010.
Sekhar SC, Chong K. Heat pipe application for energy efficient air-conditioning in an animal care facility. InIAQVEC 2007-The 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings.2007:28-31.
Yu FW, Chan KT. Optimization of water-cooled chiller system with load-based speed control. Applied Energy. 2008;85(10):931-50.
Huang S, Zuo W. Optimization of the water-cooled chiller plant system operation. 2014 sep 10-12; Atlanta, GA ,ASHRAE.2014.
Sai BB, Swathi I, Prasanna KS,et al.Design of cooling tower. International Journal of Scientific & Engineering Research. 2013;4(5):1560.
Afshari F, Dehghanpour H. A Review Study On Cooling Towers; Types, Performance and Application. ALKÜ Fen Bilimleri Dergisi. 2018:1-0.
Kareem FA, Al-Dulaimi MJ, Lafta NS. Investigation the exergy performance of a forced draft wet cooling tower. International Journal of Engineering & Technology. 2018;7(4):2575-80.
Yu BF, Hu ZB, Liu M,et al. Review of research on air-conditioning systems and indoor air quality control for human health. International journal of refrigeration. 2009;32(1):3-20.
Goetzler W, Guernsey M, Young J,et al.The future of air conditioning for buildings. Navigant Consulting, Burlington, MA (United States); 2016.