A venturi flume is a device used to measure discharge in open channel. It consists of a convergent section followed by throat and a diverging section. The venturi flume normally occupies full width of channel on actual field. The present study proposes a new design of miniature venturi flume with reduction in width. The width reduction ratios of miniature flume to channel width (b/B) considered in the project are 0.33, 0.50 and 0.66.The purpose of doing such reduction is to investigate the possibility of saving of construction cost. At the same time to carry out calibration of miniature venturi flume so that it can still be used as flow measuring device in open channels. At present the experimentation with one of the miniature venturi flumes (b/B=0.50) is completed and rest two tests are in process. The experimental results are found to be satisfactory and presented herewith.
References
Tony L. Wahl. Performance Limits of Width contracted flumes. EWRI/IAHR Conference on Hydraulic Measurement and Experimental Methods, Colorado, July 28 to August 1, 2002.
Mustafa Gogusa, Issam A. Al-Khatib, Ahmet E. Atalay. Effect of the downstream transition region of a flow measurement flume of rectangular compound cross section on flow properties. Flow Measurement and Instrumentation. 2013; 33(2012): 88–95.
Willi H. Hager. Venturi flume of minimum space requirements. J. Irrig. Drain Eng. 1989 115 (5): 913-913.
Samad Emamgholizadeh and Kazem Assare. Investigation of the upstream and downstream slope of the long-throated flumes on the discharge coefficient ARPN Journal of Engineering and Applied Sciences. 2008;3(2): 62–70.
Ali R. Vatankhah, A. Madhavi. Simplified procedure for design of long throated flumes and weirs. Flow Measurement and Instrumentation 26(2012):79–84.
Tom Gill, Robert Einhellig. Submerged venturi flume. Proceedings of SCADA and Related Technologies for Irrigation District Modernization – A USCID Water Management Conference. October 26-29, 2005 Vancouver, WA.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |