Performance Assessment of IRT Method for Distillation Model Control

S.A. Misal, V.S. Sathe

Abstract


A Wood and Berry distillation column was considered for experimentation and the Improved Relay Tuning (IRT) method was applied for design of optimum PID settings. The closed loop response was obtained using optimum values of PID parameters and compared with that of conventional relay method and other non relay method. The integral square error (ISE) criterion for the performance assessment was used and it was found that the integral error has been decreased by IRT method as compared to other methods. Hence the improved relay tuning method gives better performance for distillation column model.

Keywords: IRT, distillation, simulink, control ISE

Cite this Article

Misal SA, Sathe VS. Performance Assessment of IRT Method for Distillation Model Control. Journal of Control & Instrumentation. 2015; 6(1): 27–30p.