Operation of isolated DFIG with Modified P&O MPPT Algorithm

Komal Bagai, Sandeep Banerjee, Nikunj Kumar Agarwal, Sidharth Talia, Himanshu Sharma

Abstract


Abstract

This paper demonstrates validation of modified control algorithm for MPPT (Maximum Power Point Tracking) for Doubly Fed Induction Generator (DFIG) based WECS (Wind Energy Conversion System). The main objective is maximizing the wind energy by optimizing the losses. MPPT algorithm implementation is done by performing control of duty cycle of DC to DC boost converter. This method establishes effective system for wind energy utilization and reduces rating for control. The implementation of the MPPT algorithm is done with the use of instantaneous values of input-side electrical parameters. The complete idea is verified by simulation in the simulation environment of MATLAB—Simulink.

Keywords: MPPT, duty cycle, DFIG, WECS

Cite this Article

Komal Bagai, Sidharth Talia, Sandeep Banerjee, Himanshu Sharma, Nikunj Kumar Agarwal. Operation of isolated DFIG with Modified P&O MPPT Algorithm. Journal of Semiconductor Devices and Circuits. 2020; 7(1): 29–33p.



References


Ahmad MA, Hao MR, Ismail RMTR, Nasir ANK. Model-free wind farm control based on random search. IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS), 2016, October, pp. 131–134.

Huang C, Li F, Jin Z. Maximum power point tracking strategy for large-scale wind generation systems considering wind turbine dynamics. IEEE Transactions on Industrial Electronics. 2015;62(4):2530–2539.

Ahmad MA, Ismail RR. A data-driven sigmoid-based PI controller for buck-converter powered DC motor. IEEE Symposium on Computer Applications & Industrial Electronics (ISCAIE), 2017. 2017, April; pp. 81–86.

JA Baroudi, V Dinavahi, AM Knight. A review of power converter topologies for wind generators. Renewable Energy. 2007;32:2369–2385.

García-Rodríguez V, Silva-Ortigoza R, Hernández-Márquez E, García-Sánchez J, Taud H. DC/DC Boost converter–inverter as driver for a DC motor: Modeling and experimental verification. Energies. 2018;11(8):2044.

Hussein MM, Orabi M, Ahmed ME, Sayed MA. Simple sensorless control technique of permanent magnet synchronous generator wind turbine. 2010 IEEE International Conference on Power and Energy (PECon), Nov. 29 2010–Dec. 1 2010, pp.512–517.

R Sharma, SK Bagh, S Banerjee. A novel approach of grid connected wind energy conversion system with modified maximum power point tracking. IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), Bengaluru, 2012, pp. 1–5.

R Sharma, P Samuel, SK Bagh, S Banerjee. A grid interconnected WECS with modified MPPT. 2nd International Conference on Power, Control and Embedded Systems (ICPCES), Allahabad, 2012, pp. 1–6.

Mahmood Mirzaei, Mohsen Soltani, Niels K Poulsen, Hans H Niemann. Model based active power control of a wind turbine. American Control Conference (ACC) 2014, pp. 5037–5042.

García-Rodríguez VH, Silva-Ortigoza R, Hernández-Márquez E, García-Sánchez JR, Ponce-Silva M, Saldaña-González G. A DC motor driven by a DC/DC Boost converter-inverter: Modeling and simulation. Proceedings of the 2016 International Conference on Mechatronics, Electronics and Automotive Engineering, ICMEAE 2016, Cuernavaca, Morelos, Mexico, 22–25 November 2016; pp. 78–83.

G Martínez-Teran, A García-Barrientos, F Coyotl-Mixcoatl, R Tapia-Olvera. Design and implementation of a FLC for CD-CD converters using a microcontroller for PV systems. 2013 Int. Conf. on Electronics, Communications and Computing (CONIELECOMP), Cholula, 2013, pp. 158–161.

Raymond H Byrne, Tu A Nguyen, David A Copp, Babu R Chalamala, Imre Gyuk. Energy Management and Optimization Methods for Grid Energy Storage Systems. Access IEEE. 2018;6:13231–13260.

DW Hart. Power Electronics, 11th edition. New York: McGraw-Hill; 2010.




DOI: https://doi.org/10.37591/josdc.v7i1.3973

Refbacks

  • There are currently no refbacks.


Copyright (c) 2020 Journal of Semiconductor Devices and Circuits

Publisher: STM Journals, an imprint of CELNET (Consortium e-Learning Network Pvt. Ltd.)

Address: A-118, 1st Floor, Sector-63, Noida, Uttar Pradesh-201301, India

Phone no.: 0120-478-1215/ Email: [email protected]