Performance Appraisal of Two-stage On-site Domestic Wastewater Treatment System under Ambient Environment
DOI:
https://doi.org/10.3759/rtcet.v8i1.580Abstract
Abstract
The rapid growth in population has rendered the centralized sewerage systems a non-realistic option in sparsely populated areas. Consequently, an on-site wastewater treatment system (OWTS) is a viable alternative and cost-effective solution of sewerage system. Septic tanks with soil absorption systems are a simple mean of onsite treatment of the domestic wastewater. However septic tanks have low treatment efficiency along with several technical and constructional drawbacks. In order to improve the performance efficiency of conventional septic tank, a two-stage anaerobic reactor was developed. The main purpose of the study was to develop a two-stage onsite treatment system, which could become attractive from technical, economical, social and environmental viewpoints, to the technologies that are currently employed. The treatment unit consists of a cylindrical tank, where half of the volume is used as a modified septic tank and the other half as an upflow anaerobic filter. The system was operated at a hydraulic retention time of 24 h. The system was operated at ambient temperatures in laboratory-scale. During one year of continuous operation and performance evaluation, it was observed that a steady state condition was achieved after 120 days of operation without inoculation. The system was found to deliver highly satisfactory removal rates of 88.7±3% chemical oxygen demand (COD), 86.3±4% biochemical oxygen demand (BOD), and 91.4±10% total suspended solids (TSS), observed at steady state condition. It also showed a very good endurance against imposed hydraulic shock load. On account of the highly satisfactory experimental results, low cost, and no requirement of electricity, this system can be a potential alternative to the conventional septic tank in the developing countries like India.
Keywords: Anaerobic system, domestic wastewater, on-site treatment, two-stage
Cite this Article
Meena Kumari Sharma, Kazmi AA. Performance Appraisal of Two-stage On-Site Domestic Wastewater Treatment System under Ambient Environment. Recent Trends in Civil Engineering & Technology. 2018; 8(1): 20–28p.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |