Temperature Characteristics of Semi-Transparent Photovoltaic Module in a ventilated double pane window system

Authors

  • Sankar Barman
  • Hirak Ranjan Das Assam Royal Global University
  • Kalyan Kumar Das

Keywords:

Semi-Transparent, Photovoltaic Module, pane window system, Solar Photovoltaic, surface temperature

Abstract

This work presents the analysis of surface temperature characteristics of Semi-Transparent Solar Photovoltaic (STSPV) module integrated double pane window systems. The four systems are investigated with three types of air ventilation arrangements and a non-ventilation provision. The whole building simulation software EnrgyPlus and WINDOW 7.3 have been used to generate and analyze the required data. The focal points of the analysis include reduction in SPV module temperature and maintenance of temperature of the surface adjacent to the occupant’s area. The analysis of results shows that the introduction of ventilated air cavity reduces SPV module temperature. Due to air circulation, the highest reduction in SPV module temperature of 10.4 °C has been found during the winter season. The high ambient temperature resulted in a comparatively lower reduction (4.6 °C) in the summer season.

References

Green MA, Emery K, Hishikawa Y, Warta W, Dunlop EW. Solar cell efficiency tables (version

. Progress in Photovoltaic: Research and Applications. 2016; 24(1): 3–11.

TT Chow, KF Fong, W He, Z Lin, ALS Chan. Performance evaluation of a PV ventilated window

applying to office building of Hong Kong. Energy and Buildings. 2007; 39: 643–650.

Wong PW, Shimoda Y, Nonaka M, Inoue M, Mizuno M. Semi-transparent PV: Thermal

performance, power generation, daylight modelling and energy saving potential in a residential

application. Renewable Energy. 2008; 33(5): 1024–1036.

Peng J, Lu L, Yang H. An experimental study of the thermal performance of a novel photovoltaic

double-skin facade in Hong Kong. Solar Energy. 2013; 97: 293–304.

Khai Ng Poh. Semi-transparent building integrated photovoltaic (BIPV) windows for the tropics.

National University of Singapore. (Accessed April, 2016).

http://www.scholarbank.nus.edu.sg/bitstream/handle/10635/49121/Thesis%20(FINAL)%20dtd%2

pdf?sequence.

Jong-Ho Yoon, Se-Ra Shim, Young Sub An, Kwang Ho Lee. An experimental study on the

annual surface temperature characteristics of amorphous silicon BIPV window. Energy and

Buildings. 2013; 62: 166–175.

KE Park, GH Kang, HI Kim, GJ Yu, JT Kim. Analysis of thermal and electrical performance of

semi-transparent photovoltaic (PV) module. Energy. 2010; 35: 2681–2687.

Chae YT, Kim J, Park H, Shin B. Building energy performance evaluation of building integrated

photovoltaic (BIPV) window with semi-transparent solar cells. Applied Energy. 2014; 129: 217–

Engineering. Engineering Reference. The Reference to EnergyPlus Calculations. Washington DC,

USA: US Department of Energy; 2014.

Didone EL, Wagner A. Semi-transparent PV windows: A study for office buildings in Brazil.

Energy and Buildings. 2013; 67: 136–142.

Input Output. Input Output Reference: The Encyclopedic Reference to EnergyPlus Input and

Output. Washington DC, USA: US Department of Energy; 2014.

DL King, WE Boyson, JA Kratochvill. Photovoltaic Array Performance Model: SAND2004-

Albuquerque, New Mexico: Photovoltaic System R&D Department Sandia National

Laboratories; 2004

Published

2022-02-09

Issue

Section

Research Article