Six Sigma DMAIC Approach for Increasing Effectiveness of Heat Exchanger
Keywords:
Six Sigma, DMAIC, CTQ, quality, effectiveness, furnace, shell, tube heat exchangerAbstract
In a small sized furnace manufacturing company, heat exchanger is a fundamental segment. The productivity of the furnace relies on upon the proficiency and adequacy of the heat exchanger. This research uncovers the experimental execution of Six Sigma DMAIC (DefineMeasure-Analyze-Improve-Control) stages to enhance the adequacy of shell and tube heat exchanger and along these lines enhance the quality and productivity of the furnace. The basic goal is to enhance the nature of the furnace through DMAIC stages. In this case study, the define phase assesses the furnace performance, through distinguishing and lessening different multiple operational energy losses to enhance the general proficiency. In measure stage, the present effectiveness of the heat exchange rate for the heat exchanger was measured and found as 0.61. In analysis stage, there as on for the lessening of effectiveness was distinguished as less heat exchange area through cause and effect diagram. In improve stage; the existing design was modified through various alternative solutions such as factors that identify the performance of heat exchanger by conducting brain storming sessions. In this stage, the solution was identified with the introduction of circular fins over the bare tubes to improve the effectiveness in the shell and tube heat exchanger. Therefore, the effectiveness has been raised from 0.61 to 0.664. In control stage, the control techniques were prescribed to manage the upgrades in shell and tube heat exchanger.
Cite this Article Akash A Shukla, Dhaval B Patel. Six Sigma DMAIC approach for increasing effectiveness of Heat Exchanger, Trends in Machine Design. 2016; 3(3): 12–17p.
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |